Xantrex Programmable Power
Programmable Power Products
Elgar, Sorensen and Xantrex Products
DC Products Bench Products AC Products Modular AC / DC Electronic Loads Custome Solutions
Overview Features Specifications Technical Diagrams Downloads Get a Quote  
DCS Series : Specifications
Common
Meter Accuracy 1% of full scale + 1 count
Max. Voltage Differential from Output to Safety Ground 150 VDC
Remote Start/Stop and Interlock TTL compatible input or 12-250 VAC (12-130 VDC) or a contact closure
Cooling Internal fan, over temperature shutdown if internal heat sink exceeds set temperature
Remote Sense The maximum allowed sense line drop is 4V per line (2V on the DCS 8/10V 1 kW/1.2 kW models and 1V/line for all 3 kW models). Line drop subtracts from the maximum available output voltage at full rated power.
Remote Programming Enabled via external jumper on rear panel connector J3
Overvoltage Protection Crowbar type adjustable from 5-110% of rated output using front panel control (local or remote program selectable via J3 jumper)
Remote Analog Programming Linearity ±1% Accuracy: ±5%
Regulatory Certified to UL/CSA 61010 and IEC/EN 61010-1 CE Compliant (LVD and EMC directive)
Input: Voltage and Frequency
Output Power 200 - 250 VAC 100 - 132 VAC 190 - 250 VAC
1kW single phase, 8A typical, 47- 63 Hz single phase, 15A typical, 47-63 Hz, internal jumper selectable  
1.2kW single phase, 9A typical, 47-63 Hz single phase, 18A typical, 47-63 Hz, internal jumper selectable  
3kW single-phase, 20A,
47- 63Hz.
  three phase, 14A, 47-63Hz.
Output: Voltage and Current
1kW Model Voltage Current
DCS 8-125E 0 - 8 0 - 125
DCS 10-100E 0 - 10 0 - 100
DCS 20-50E 0 - 20 0 - 50
DCS 33-33E 0 - 33 0 - 33
DCS 40-25E 0 - 40 0 - 25
DCS 50-20E 0 - 50 0 - 20
DCS 60-18E 0 - 60 0 - 18
DCS 80-13E 0 - 80 0 - 13
DCS 100-10E 0 - 100 0 - 10
DCS 150-7E 0 - 150 0 - 7
DCS 300-3.5E 0 - 300 0 - 3.5
DCS 600-1.7E 0 - 600 0 - 1.7
1.2kW Model Voltage Current
DCS 8-140E 0 - 8 0 - 140
DCS 10-120E 0 - 10 0 - 120
DCS 20-60E 0 - 20 0 - 60
DCS 33-36E 0 - 33 0 - 36
DCS 40-30E 0 - 40 0 - 30
DCS 50-24E 0 - 50 0 - 24
DCS 60-20E 0 - 60 0 - 20
DCS 80-15E 0 - 80 0 - 15
DCS 100-12E 0 - 100 0 - 12
DCS 150-8E 0 - 150 0 - 8
DCS 300-4E 0 - 300 0 - 4
3kW Model Voltage Current
DCS 8-350E 0 - 8 0 - 350
DCS 12-250E 0 - 12 0 - 250
DCS 20-150E 0 - 20 0 - 150
DCS 40-75E 0 - 40 0 - 75
DCS 55-55E 0 - 55 0 - 55
DCS 60-50E 0 - 60 0 - 50
DCS 80-37E 0 - 80 0 - 37
DCS 150-20E 0 - 150 0 - 20
Output
Voltage Resolution 0.02%
Ripple (mV rms or p-p) See table
Regulation Line For input voltage variation over the AC
input voltage range, with constant rated load.
Load For 0-100% load variation, with constant
nominal line voltage.
Voltage 0.1%
Current 0.1%
Transient Response Typically recovers in 500 μs (1 & 1.2 kW) or 1ms (3k W) to 1% of steady-state output voltage (within 1% of Vmax) for 70-100% or 100-70% load change.
Stability ±0.05% of maximum voltage or current over 8 hours after 30 minute warm-up time at fixed line, load and temperature
Efficiency See table below Temperature Coefficient: 0.02%/°C of maximum output voltage; 0.03%/°C of maximum output current. Change in output per °C change in ambient temperature, with constant line and load
Physical
Dimensions Width:
19” (482 mm) W, Depth 17.52” (445 mm)
  Height:
1 kW and 1.2 kW: 1U or 1.72” (43 mm)
3 kW: 2U or 3.46” (87 mm)
Weight & Shipping Weight
Weight 1 kW and 1.2 kW: 19 lbs. ( 8.6 kg)
3 kW: 33 lbs. (15 kg)
Shipping Weight 1 kW and 1.2 kW: 24 lbs. (10.9 kg)
3 kW: 42 lbs. (19 kg)
Environmental
Operating Temperature 0°C to 50°C (no derating)
Storage Temperature -55°C to 85°C
Humidity Range 0 to 80% RH, non condensing
Investigate our discount web specials
  Product Configurator  
DC Electronic Loads
DC Modular Supply
Discontinued Products
Product Support
Contact Sales

Programming & Read-back Specifications
Output
Output
J3 Connector
1 90-250 VAC Remote Shutdown 14 TTL Shutdown
2 Shutdown Return 15 +12 VDC
3 OVP Program 16 1 mACurrent Source (OVP)
4 Remote/Local Status Indicator 17 OVP Indicator
5 Mode Status Indicator 18 Thermal S/DN Status
6 Ground 19 0-5V Voltage Monitor
7 0-5V Current Monitor 20 Remote Voltage Select
8 Voltage Control 21 1 mA Current Source (V)
9 Voltage Program Input 22 1 mA Current Source (I)
10 Current Program Unit 23 1 mA Current Source (I)
11 Current Control 24 Return
12 Return Sense 25 POS Output (8-100V Models Only)
13 POS Sense (8-100V Models Only)