| Output Voltage and Current |
|
| Model |
Voltage |
Current |
| HPD 15-20 |
0-15 |
0-20 |
| HPD 30-10 |
0-30 |
0-10 |
| HPD 60-5 |
0-60 |
0-5 |
|
 |
|
 |
|
| Operating Temperature |
0 to 50°C (derated
above 30°C) |
| Storage Temperature |
-55°C to 85°C |
| Cooling |
By convection |
| Efficiency |
80% |
| Series Operation |
Consult factory. |
| Parallel Operation |
Consult factory. |
| Overvoltage Protection |
Available with Options
M5A and M9B |
| Overload Short-Circuit Protection |
Standard,
switches to current mode operation while in
short circuit |
| Output to Chassis Isolation |
400 VDC |
| Voltage Resolution |
Standard 0.02%, IEEE-488 |
| Meter Accuracy |
1% of full scale + 1 count |
| Voltage Programming |
Zero to full scale output
linearly proportioned to a 0-10V or 0-10 kΩ
(Option M5A) |
| Current Programming |
Zero to full scale output
linearly proportioned to 0-10V or 0-10 kΩ(Option
M5A) |
| Remote Sensing |
Compensation for maximum
line drop of 0.5V (per output line) |
| Rear Access Connector |
Option M5A.
D subminiature 25 pin female. Option M9B IEEE-
488 connector (mating connector not supplied) |
| Regulatory Compliance |
Regulatory Compliance: CE Mark |
| Constant Voltage Mode |
| Ripple and Noise |
5 mV rms and 100 mV p-p
max. |
| Regulation |
Line: 0.01% of V max. + 2 mV. For input voltage
variation over the AC input voltage range, with
constant rated load.
Load: 0.01% of V max. + 2 mV. For 0-100% load
variation, with constant nominal line voltage. |
| Transient Response |
Typically recovers in<500 μs to within 0.05% of steady-state output
voltage. ±50% load change in the range of 25 to
100% of rated load |
| Stability |
0.02% of maximum voltage over
8 hours after 60 minute warm up time at fixed
line, load and temperature |
| Temperature Coefficient |
0.015%/°C of maximum
output voltage. Change in output per °C
change in ambient temperature, with constant
line and load. |
| Constant Current Mode |
| Regulation |
Line: 0.01% of I max. + 1 mA. For input voltage
variation over the AC input voltage range, with
constant rated load.
Load: 0.01% of I max. + 1 mA. For 0-100% load
variation, with constant nominal line voltage. |
| Temperature Coefficient |
0.02%/°C of maximum
output current. Change in output per °C
change in ambient temperature, with constant
line and load. |
| Stability |
0.03% of maximum current over 8
hours after 60 minute warm |
|
 |
|
 |
|
| Voltage and Frequency |
115 VAC single phase±10%, 47-63 Hz, or optional 200 to 250 VAC
(M2) |
| Current |
6A max |
|
 |
|
 |
|
| Dimensions |
3U or 5.25” (133 mm) H x
4.25” (108 mm) W x
11.50” (292 mm) D |
| Weight |
7.7 lbs. (3.5 kg) |
| Shipping Weight |
9 lbs. (4 kg) |
|
 |
|
 |
|
 |
|

|
 |
 |
| M5A: J-305 Pin Assignments |
|
| 1 |
Overvoltage Protection Flag |
14 |
Not Used |
| 2 |
TTL Shutdown Return |
15 |
TTL Shutdown |
| 3 |
Not Used |
16 |
Current Limit Program |
| 4 |
Program Return |
17 |
Voltage Program |
| 5 |
Program Return |
18 |
Current Readback |
| 6 |
Auxiliary Ground |
19 |
Voltage Readback |
| 7 |
Remote Voltage Program Select |
20 |
+10V Reference Out (10 mA max.) |
| 8 |
Remote Current Program Select |
21 |
Output Fail Flag |
| 9 |
Voltage Current Limit Mode Indicator |
22 |
+ Sense |
| 10 |
+ Out |
23 |
+ Out |
| 11 |
+ Out |
24 |
- Return |
| 12 |
- Return |
25 |
- Sense |
| 13 |
- Return |
|
|
|
 |
 |
|
 |