| Regulation |
Line: For input voltage variation over the AC input voltage range, with constant rated load.
Load: For 0-100% load variation, with constant nominal line voltage.
Voltage: 0.1% of maximum rated output
Current: 0.5% of maximum rated output |
| Power Factor |
0.72 min. |
| Series Operation |
Up to 2 units (See Output Float Voltage) |
| Transient Response |
A 30% current step load will recover to within ±2% of set voltage within 10 msec. |
| Stability |
±0.05% of set point per 8 hours after 30 minutes warm-up at fixed line, load and temperature. |
| Temperature Coefficient |
0.02%/°C of rated output voltage
0.03%/°C of rated output current
Change in output per °C change in ambient temperature, with constant line and load |
| Operating Temperature |
0 to +50° C, No derating |
| Storage Temperature |
-20 to +70°C |
| Cooling |
Internal fans |
| Controls (Front Panel) |
On/Off switch, DC volts adjust, DC amps adjust, OVP preset adjust (limit set) |
| Meters/Indicators |
LCD DC voltmeter, ammeter and OVP limit set. LED indicators for voltage mode, current mode. OVP fault and fault |
| Built-In Protection |
Over Voltage, Current limit Fold back, Over Temperature, Brown Out, Turn On Surge Limit,
Slow Start |
Remote Control/Monitor
(Rear Panel) |
On/Off control via contact closure, 6-120 VDC, TTL or CMOS switch, output voltage and current monitor, OVP limit set, summary fault status on
P60 Series. |
| Remote Programming |
|
Voltage (0 to 100%) |
Current (0 to 100%) |
| Resistive |
0-5K ohms |
0-5K ohms |
| Voltage |
0-5 VDC or 10 VDC |
0-5 VDC or 10 VDC |
| Remote Sensing |
Terminals provided to sense output voltage at load. Line drop subtracts from the maximum available output voltage at full rated power. |
| Operational Features |
Master/Slave, Series, Parallel |
| Primary Power (Standard) |
P63C and P66C
190-253 VAC2 |
| Regulatory |
CE Compliant (LVD and EMC directive) |
|
 |
|
 |
|
| Input Voltage |
190-253 VAC, 47-63 Hz (Standard)
360-440 VAC, 47-63 Hz (Option)
432-528 VAC, 47-63 Hz (Option) |
Input Current
@ 208 VAC (Typical) |
At 13 kW Output: 54 A
At 16.5 kW Output: 67 A
At 20 kW Output: 80 A
Operates from Delta or Wye Source |
|
 |
|
 |
|
| Dimensions |
19” (W) X 10.5” (H) X 22” (D) |
| Weight |
13 kW: 120 Lbs.
16.5 kW: 140 Lbs.
20 kW: 160 Lbs. |
|
 |
|
 |
|
| AC Input Interface |
3 wire + GND (#1/4-20 threaded studs) (208 VAC) |
| 3 wire + GND (#1/4-20 threaded studs) (208 VAC) |
3 wire + GND (#1/4-20 threaded studs) (208 VAC) Bus bars with 0.410” interface holes for output ≤50 VDC. |
Control/Monitor
Interface |
DB 25-pin female connector
|
|
 |
|
 |
| Output: Voltage and Current Ranges |
|
| Model |
Output DC |
Output
p-p Ripple |
| Volts |
Amps |
| P66C-52000 |
0-5 |
2000 |
50 mV |
| P66C-52500 |
0-5 |
2500 |
50 mV |
| P66C-53000 |
0-5 |
3000 |
50 mV |
| P66C-81600 |
0-8 |
1600 |
50 mV |
| P66C-82000 |
0-8 |
2000 |
50 mV |
| P66C-82400 |
0-8 |
2400 |
50 mV |
| P66C-101300 |
0-10 |
1300 |
50 mV |
| P66C-101650 |
0-10 |
1650 |
50 mV |
| P66C-102000 |
0-10 |
2000 |
50 mV |
| P66C-12.51060 |
0-12.5 |
1060 |
50 mV |
| P66C-12.51325 |
0-12.5 |
1325 |
50 mV |
| P66C-12.51600 |
0-12.5 |
1600 |
50 mV |
| P66C-15880 |
0-15 |
880 |
50 mV |
| P66C-151100 |
0-15 |
1100 |
50 mV |
| P66C-151320 |
0-15 |
1320 |
50 mV |
| P66C-20665 |
0-20 |
665 |
75 mV |
| P66C-20830 |
0-20 |
830 |
75 mV |
| P66C-201000 |
0-20 |
1000 |
75 mV |
| P66C-25520 |
0-25 |
520 |
75 mV |
| P66C-25650 |
0-25 |
650 |
75 mV |
| P66C-25800 |
0-25 |
800 |
75 mV |
| P66C-30440 |
0-30 |
440 |
75 mV |
| P66C-30550 |
0-30 |
550 |
75 mV |
| P66C-30660 |
0-30 |
660 |
75 mV |
| P66C-50265 |
0-50 |
265 |
75 mV |
| P66C-50330 |
0-50 |
330 |
75 mV |
| P66C-50400 |
0-50 |
400 |
75 mV |
|
 |
|
 |
| Remote Computer Programming Options |
|
| IEEE 488.2 and RS 232 Interface Option enables the power supply to be operated from a computer with full remote programming control and monitoring. The slave interface option allows multichannel control from a single bus address. |
| Programming Resolution |
Voltage: 0.03% of full scale
Current: 0.03% of full scale
Over voltage Protection: 0.03% of full scale
(full scale is 120% of maximum output voltage) |
| Programming Accuracy |
Voltage: ± (0.1% + 0.1% of maximum output voltage)
Current: ± (0.1% + 0.4% of maximum output voltage)* |
| Overvoltage Protection |
± (0.5% + 0.5% of maximum output voltage) |
| Readback Resolution |
Voltage and Current: ± 0.03% of full scale |
| Readback Accuracy |
Voltage: ± (0.1% + 0.15% of full scale output voltage)
Current: ± (0.1% + 0.4% of full scale output current)*
|
| * After 30 minutes operation with fixed line, load and temperature. |
|
 |
|
 |
|
| Programmable Functions |
• Output Voltage and Current
• Soft Limits for Voltage and Current
• Over Voltage Protection
• Output Enable/Disable
• Maskable Fault Interrupt
• Hold and Trigger |
| Readback Functions |
• Actual Measured Voltage and Current
• Voltage and Current Settings
• Soft Voltage and Current Limits
• Over Voltage Protection Setting
• Status and Accumulated Status Registers
• Programming Error Codes
• Fault Codes
• Manufacturer, Power Supply Model and
Firmware Version Identification
|
|
 |
|
 |
|
 |
|

|
 |
 |