Power Ten P66 : Specifications
Common
Regulation Line: For input voltage variation over the AC input voltage range, with constant rated load.
Load: For 0-100% load variation, with constant nominal line voltage.
Voltage: 0.1% of maximum rated output
Current: 0.5% of maximum rated output
Power Factor 0.72 min.
Series Operation Up to 2 units (See Output Float Voltage)
Transient Response A 30% current step load will recover to within ±2% of set voltage within 10 msec.
Stability ±0.05% of set point per 8 hours after 30 minutes warm-up at fixed line, load and temperature.
Temperature Coefficient 0.02%/°C of rated output voltage
0.03%/°C of rated output current
Change in output per °C change in ambient temperature, with constant line and load
Operating Temperature 0 to +50° C, No derating
Storage Temperature -20 to +70°C
Cooling Internal fans
Controls (Front Panel) On/Off switch, DC volts adjust, DC amps adjust, OVP preset adjust (limit set)
Meters/Indicators LCD DC voltmeter, ammeter and OVP limit set. LED indicators for voltage mode, current mode. OVP fault and fault
Built-In Protection Over Voltage, Current limit Fold back, Over Temperature, Brown Out, Turn On Surge Limit, Slow Start
Remote Control/Monitor
(Rear Panel)
On/Off control via contact closure, 6-120 VDC, TTL or CMOS switch, output voltage and current monitor, OVP limit set, summary fault status on P60 Series.
Remote Programming   Voltage (0 to 100%) Current (0 to 100%)
Resistive 0-5K ohms 0-5K ohms
Voltage 0-5 VDC or 10 VDC 0-5 VDC or 10 VDC
Remote Sensing Terminals provided to sense output voltage at load. Line drop subtracts from the maximum available output voltage at full rated power.
Operational Features Master/Slave, Series, Parallel
Primary Power (Standard) P63C and P66C
190-253 VAC2
Regulatory CE Compliant (LVD and EMC directive)
Input
Input Voltage 190-253 VAC, 47-63 Hz (Standard)
360-440 VAC, 47-63 Hz (Option)
432-528 VAC, 47-63 Hz (Option)
Input Current
@ 208 VAC (Typical)
At 13 kW Output: 54 A
At 16.5 kW Output: 67 A
At 20 kW Output: 80 A
Operates from Delta or Wye Source
Physical
Dimensions 19” (W) X 10.5” (H) X 22” (D)
Weight 13 kW: 120 Lbs.
16.5 kW: 140 Lbs.
20 kW: 160 Lbs.
Interface
AC Input Interface 3 wire + GND (#1/4-20 threaded studs) (208 VAC)
3 wire + GND (#1/4-20 threaded studs) (208 VAC) 3 wire + GND (#1/4-20 threaded studs) (208 VAC) Bus bars with 0.410” interface holes for output ≤50 VDC.
Control/Monitor
Interface

DB 25-pin female connector

Output: Voltage and Current Ranges
Model Output DC Output
p-p Ripple
Volts Amps
P66C-52000 0-5 2000 50 mV
P66C-52500 0-5 2500 50 mV
P66C-53000 0-5 3000 50 mV
P66C-81600 0-8 1600 50 mV
P66C-82000 0-8 2000 50 mV
P66C-82400 0-8 2400 50 mV
P66C-101300 0-10 1300 50 mV
P66C-101650 0-10 1650 50 mV
P66C-102000 0-10 2000 50 mV
P66C-12.51060 0-12.5 1060 50 mV
P66C-12.51325 0-12.5 1325 50 mV
P66C-12.51600 0-12.5 1600 50 mV
P66C-15880 0-15 880 50 mV
P66C-151100 0-15 1100 50 mV
P66C-151320 0-15 1320 50 mV
P66C-20665 0-20 665 75 mV
P66C-20830 0-20 830 75 mV
P66C-201000 0-20 1000 75 mV
P66C-25520 0-25 520 75 mV
P66C-25650 0-25 650 75 mV
P66C-25800 0-25 800 75 mV
P66C-30440 0-30 440 75 mV
P66C-30550 0-30 550 75 mV
P66C-30660 0-30 660 75 mV
P66C-50265 0-50 265 75 mV
P66C-50330 0-50 330 75 mV
P66C-50400 0-50 400 75 mV
Remote Computer Programming Options
IEEE 488.2 and RS 232 Interface Option enables the power supply to be operated from a computer with full remote programming control and monitoring. The slave interface option allows multichannel control from a single bus address.
Programming Resolution Voltage: 0.03% of full scale
Current: 0.03% of full scale
Over voltage Protection: 0.03% of full scale
(full scale is 120% of maximum output voltage)
Programming Accuracy Voltage: ± (0.1% + 0.1% of maximum output voltage)
Current: ± (0.1% + 0.4% of maximum output voltage)*
Overvoltage Protection ± (0.5% + 0.5% of maximum output voltage)
Readback Resolution Voltage and Current: ± 0.03% of full scale
Readback Accuracy

Voltage: ± (0.1% + 0.15% of full scale output voltage)
Current: ± (0.1% + 0.4% of full scale output current)*

* After 30 minutes operation with fixed line, load and temperature.
Programming
Programmable Functions • Output Voltage and Current
• Soft Limits for Voltage and Current
• Over Voltage Protection
• Output Enable/Disable
• Maskable Fault Interrupt
• Hold and Trigger
Readback Functions • Actual Measured Voltage and Current
• Voltage and Current Settings
• Soft Voltage and Current Limits
• Over Voltage Protection Setting
• Status and Accumulated Status Registers
• Programming Error Codes
• Fault Codes
• Manufacturer, Power Supply Model and Firmware Version Identification

 