AC 1 phase:115/120/200/208/230V ±10%
AC 3 phase: 115/200 or 120/208V ±10%
delta and wye
AC 3 phase: 230/400V ±10% wye – neutral
AC Voltage Range: 103.5V to 253V
DC Voltage Range: 210V to 300V (314V for 2
sec.)
Power Factor: ≥0.95
Frequency range
47Hz to 63Hz, DC
Input Connector
Amphenol, DL3102A24-10P or Phoneix style
Mating Connector
Amphenol, DL3106A24-10P
Common
Module Interface
Backplane
Slot Positions: 12 slots Multi-module
control interface
Configuration Guidelines
Up to 8 Chassis may be interconnected.
Paralleled AC, DC and Load modules must be in
adjacent slots and be like modules. AC modules
to be configured for multi-phase operation must
be in adjacent slots.
Regulatory
Certified to UL 61010-1, CSA C22.2 No. 61010.1 and
IEC/EN 61010-1.
Compliance with EN61326 and FCC 21 CFR, Subpart J
CE Mark is to EMC and LVD
All specifications are subject to change
Environmental - Common
Operating Temperature
-10° C to 50° C Extended operating range available
Storage Temperature
-40° C to 70 °C
Operating Humidity
Range
95%, non-condensating
Altitude
up to 2,000 M Extended operating range available
Shock and vibration
Class 3 Mil-PRF-28800F
Physical
Dimensions
EIA RS-310 rack mount : Wide
7” (177.8mm) (4U) : High
17”(432 mm) : Depth