Output

Output Power: 1750 VA, 3500 VA or 5250 VA

Output Phase: 1750 VA, 1 phase; 3500 VA, 1 or 2 phase; 5250 VA, 1, 2 or 3 phase

AC Output Voltage: 0 to 156 VRMS L-N low range; 0 to 312 VRMS high L-N range

DC Output Voltage: 0 to 233V low range; 0 to 445V high range

Output Current Per Phase: 13A to 135V in 156V range; 6.5A to 270V in 312V range (per 1750 VA module)

Power Factor of Load: 0 lagging to 0 leading

Crest Factor: 4.0 (peak output current to RMS output current)

Output Frequency Range: 45 Hz to 500 Hz

Max Total Harmonic Distortion (Full Linear Load or No Load): 0.3% max

AC Noise Level: 60 dB RMS below full output voltage

Amplitude Stability With Remote Sense: ±0.1% of full scale over 24 hours at constant line, load and temperature

Line Regulation: 0.05% of full scale for a ±10% change in line voltages

Load Regulation: 0.15% of full scale

Voltage Accuracy: ±0.1% of full scale

Voltage Resolution: 0.03% of full scale

Frequency Resolution: 0.1 Hz

Phase Accuracy, Phase-to-Phase Balanced Linear Resistive Load: ±1°

Phase Angle Resolution: 0.1°

Remote Output Voltage Sense: 5 VRMS total lead drop, max

Investigate our discount web specials
  Product Configurator  
AC Electronic Loads
AC Modular Supply
Discontinued Products
Product Support
Contact Sales

Measurements

  • Peak Inrush Current
  • Phase to Neutral RMS Output Voltages
  • Phase to Phase RMS Output Voltages
  • RMS Output Currents
  • Peak Current
  • Output Frequency
  • 1Ø to 3Ø Power
  • 1Ø to 3Ø VA
  • Power Factor
  • Output Phase Angles Relative to Phase A

Measurement Accuracy: All at 25° ± 5°C

Power: 2.5% of full scale

Voltage: 0.3% of full scale + 0.2% of reading

Current: 0.3% of full scale + 0.5% of reading

Apparent Power: 2.5% for output > 200 VA

Frequency: 0.25%

Phase: 0.5°


Input

Input Voltage Ranges: Factory configured 187 to 264 VRMS, 3Ø L-L (3 wire), or 342 to 457 VRMS, 3Ø L-L (4 wire). A chassis ground is also required.

Input Power Factor: 0.6 (0.99 with input PFC option, 0.35 for European rectifier input)

Input Frequency Range: 47 to 63 Hz

Efficiency: 70% min, at full load

Ride Through: 3 ms, min for rectifier input; 10 ms, min, with PFC option


Protection and Safety

Overvoltage Shutdown: Programmable for 20V to 255V peak, 156V range; 40V to 510V peak, 312V range

Programmable Current Limit Shutdown: Settable to 1% of range (0.5A to 13A for 156V range; 0.5A to 6.5A for 312V range)

Programmable Current Limit with Timed Shutdown: Settable to 1% for range; the timeout is settable from 10 ms to 10s

Programmable Constant Current: Settable to 1% of range (0.5A to 13A for 156V range; 0.5A to 6.5A for 312V range). For all current accuracies, add ±1.5%/kHz above 500 Hz. For paralleled amplifiers, add ±1%.

Overtemperature Shutdown: automatic, not programmable


Physical Specifications

Height: 8.75 in (222 mm)

Width: 19 in (483 mm)

Depth: 24.1 in (613 mm)