Output Ratings |
XEL 15-5 |
XEL30-3 |
XEL60-1.5 |
XEL30-3D |
|
Voltage (VDC) |
0-15 |
0-30 |
0-60 |
0-30 |
|
Current (ADC) |
0.1-5 |
0.1-3 |
0.1-1.5 |
0.1-3/6 |
|
Power (W) |
75 |
0-90 |
90 |
90/180 |
|
Output Performance |
|
Voltage Meter |
4-digit meter |
|
Accuracy |
0.1% + 10mV |
|
Resolution |
10mV |
|
Current Meter |
4-digit meter |
|
Accuracy |
0.5% + 3mA |
0.3% + 3mA |
0.3% + 3mA |
0.3% + 3mA* |
|
Resolution |
1mA |
1mA |
1mA |
1mA |
|
Low Current |
<500mA |
|
Accuracy |
0.3% + 0.3mA |
|
Resolution |
0.1mA |
|
Voltage Ripple |
0.4 mVRMS |
|
Voltage Noise |
2 mVpp |
|
Current Ripple |
5 mARMS |
|
Load Regulation |
|
Voltage |
0.01% + 2mV |
|
Current |
0.01% + 500μA |
|
Line Regulation (10% line change) |
|
Voltage |
0.01% + 2.0mV (with remote sense up to 0.5V
line Drop 0.01% + 4.5mV) |
|
Current |
0.01% + 250μA (for line resistance <0.5ohms when remote sense is used.) |
|
Transient Response |
<50μs to within 50mV of setting (90% load change) |
|
Common |
|
AC Input |
115 VAC ± 10%, 50/60Hz ( 230VAC available as option MHV ) |
|
Power |
280VA maximum |
|
Operating Temp |
5-40 °C, 20-80% RH |
|
Storage Temp |
-40 to +70 °C |
|
Weight |
9.9 lbs. / 4.5 kgs, XEL30-3D: 18.8 lbs. / 9 kgs |
|
Size (WxHxD) |
4.2x5.2x11.3 inches / 107x131x288 mm,
XEL30-3D: 8.4x5.2x11.3 inches / 214x131x288 mm |
|
Options |
|
ARM-XPDG2 |
Rackmount Kit |
| |
 |
| * Current accuracy in parallel mode = 0.5% + 3mA |
|
 |
|

|
 |
 |