AMETEK Programmable Power
Programmable Power Products
Elgar, Sorensen and Xantrex Products
DC Products Bench Products AC Products Modular AC / DC Electronic Loads Custome Solutions
Overview Features Specifications Technical Diagrams Downloads Get a Quote  
Xantrex XFR Series : Specifications
Specifications Available
1.2kW 6-200 1.2kW 7.5-140 1.2kW 12-100 1.2kW 20-60
1.2kW 35-35 1.2kW 40-30 1.2kW 60-20 1.2kW 100-12
1.2kW 150-8 1.2kW 300-4 1.2kW 600-2 2.8kW 7.5-300
2.8kW 12-220 2.8kW 20-130 2.8kW 33-85 2.8kW 40-70
2.8kW 60-46 2.8kW 100-28 2.8kW 150-18 2.8kW 300-9
2.8kW 600-4      
 

 

Electrical Specifications 1

 

Output Ratings:

 

 

 

Output Voltage

 

0-7.5 V

 

Output Current

 

0-140 A

 

Output Power

 

1050 W

 

Line Regulation: 2

 

 

 

Voltage (0.01% of Vmax + 2 mV)

 

2.5 mV

 

Current (0.01% of Imax + 2 mA)

 

10 mA

 

Load Regulation: 3

 

 

 

Voltage (0.02% of Vmax + 5 mV)

 

3 mV

 

Current (0.02% of Imax + 5 mA)

 

10 mA

 

Meter Accuracy:

 

 

 

Voltage (0.5% of Vmax + 1 count)

 

0.09 V

 

Current (0.5% of Imax + 1 count)

 

1.5 A

 

Output Noise & Ripple:

 

 

 

Voltage rms

 

5 mV

 

Voltage (p-p) (0-20 MHz)

 

50 mV

 

Current rms

 

250 mA

 

Drift (8 hours): 4

 

 

 

Voltage (0.05% of Vmax)

 

3.75 mV

 

Current (0.05% of Imax)

 

70 mA

 

Temperature coefficient: 5

 

 

 

Voltage (0.02% of Vmax/° C)

 

1.5 mV

 

Current (0.03% of Imax/° C)

 

42 mA

 

Program Slew Rate: 6

 

 

 

Rise Time

 

100 ms

 

Fall Time

 

100 ms

 

OVP adjustment range: (5% to 110% of Vmax)

 

0.375-8.25 V

 

Efficiency: 7

 

78%

 

Interface Specifications 1,9

 

Program Resolution (16-bit):

 

 

 

Voltage

 

0.13 mV

 

Current

 

2.35 mA

 

OVP

 

0.13 mV

 

Program Accuracy:

 

 

 

Voltage (0.2% + 10 mV)

 

10 mV (+/- 0.12%)

 

Current (0.3% + 10 mA)

 

500 mA (+/- 0.1%)

 

OVP (0.5%) + 100 mV)

 

80 mV

 

Readback Resolution (16-bit):

 

 

 

Voltage

 

0.13 mV

 

Current

 

2.35 mA

 

Readback Accuracy:

 

 

 

Voltage (0.2% + 20 mV)

 

30 mV (+/- 0.12%)

 

Current (0.3% + 20 mA)

 

500 mA (+/- 0.1%)

 

 

 

 

 

1. Specifications indicate typical performance at 25 ° C +/- 5° C, nominal line input of 120 VAC.

 

2. For input voltage variation over the AC input voltage range, with constant rated load.

 

3. For 0-100% load variation, with constant nominal line voltage.

 

4. Maximum drift over 8 hours with constant line, load and temperature, after 30 minutes warm-up.

 

5. Change in output per ° C change in ambient temperature, with constant line and load.

 

6. Measured with stepped 0-10 V analog programming source and a resistive load.

 

7. Typical efficiency at 100 VAC input voltage and rated output power.

 

8. Derate output current on 6 V model by 1.5 A per ° C for operating temperatures 30-50° C.

9. Apply accuracy specifications according to the following voltage program accuracy example:
    Set a model 20-60 power supply to 10 volts. The expected result will be within the range
    of 10 volts +/- 75 mV +/- 0.12% of the set voltage of 10 volts.

 

 

 

General Specifications

 

Operational AC input voltage

 

85-130 VAC or 190-264 VAC 1 phase (17 A @ 120 VAC; 8.8 A @ 230 VAC typical), 47-63 Hz. Automatic range detect.

 

Switching Frequency

 

6 V to 40 V models: nominal 78 kHz (156 kHz output ripple); 60 V to 600 V models: nominal 62.5 kHz (125 kHz output ripple).

 

Time Delay

 

7 s maximum from power on until output stable

 

Voltage Mode Transient Response Time

 

<3 ms for output voltage to recover within 0.5 % of its rated voltage after a step change in load current of up to 10% to 90% of rated output

 

Maximum Voltage Differential

 

+/-600 VDC from output to safety ground

 

Remote On/Off and Interlock

 

2.5-15 V signal or TTL-compatible input, selectable logic

 

Remote Analog Programming

 

Voltage and current programming inputs (source must be isolated): 0-5 k, 0-10 k resistances;0-5 V, 0-10 V (default) voltage sources

 

Remote Analog Monitoring

 

Voltage and current monitor outputs 0-5 V, 0-10 V (default) ranges for 0-100% of output

 

Remote Programming and Monitoring Accuracy

 

1% zero to full scale output for the default range

 

Maximum Remote Sense Line Drop Compensation

 

5 V/line (Line drop is subtracted from total voltage available at supply output)

 

Operating Temperature Range

 

32° F to 122 ° F (0° C to 50° C)

 

Storage Temperature Range

 

-4° F to 158° F (-20° C to 70° C)

 

Humidity Range

 

Up to 90% RH, non-condensing

 

Front Panel Voltage and Current Control

 

10-turn voltage and current potentiometers

 

Front Panel Voltage Control Resolution

 

0.02% of maximum voltage

 

AC Input Connector Type

 

3-terminal, 34 A/250 V, wire clamp connector with strain relief cover

 

Main Output Connector

 

6 to 40 V models: nickel-plated copper bus bars with bus bar shield; 60 V to 600 V models: 4-terminal wire clamp connector with strain relief

 

Weight (one unit)

 

18 lb (8.2 kg) approx

 

Dimensions (H x W x D)

 

1.7 x 19.0 x 20.0” (43.2 x 429.4 x 508.1 mm)

 

Options

 

GPIB-XFR1

 

GPIB Interface card (16-bit)

 

RS-232-XFR1

 

RS-232 Interface card (16-bit)

 

ISOL-XFR1

 

ISOL Interface card provides isolated analog control and readback

 

ISOL-420

 

4-20 mA isolated analog control

 

M13A

 

Locking knobs for front panel controls

 

Regulatory Approvals

 

CE-marked units meet: EN61010-1, EN61000-6-2 and EN61000-6-4; UL Listed to UL3111-1; CSA certified to CSA C22.2 No 1010.1; Meets USA EMC standard: FCC, part 15B, class A; Meets Canadian EMC standard: ICES-001, Class A.

 

Note: Specifications subject to change without notice.


Investigate our discount web specials
  Product Configurator  
DC Electronic Loads
DC Modular Supply
Discontinued Products
Product Support
Contact Sales