Xantrex Programmable Power
Programmable Power Products
Elgar, Sorensen and Xantrex Products
DC Products Bench Products AC Products Modular AC / DC Electronic Loads Custome Solutions
Overview Features Specifications Technical Diagrams Downloads Get a Quote  
Xantrex XHR Series : Specifications
Specifications Available
7.5-130 20-5033-33 40-25
60-18 100-10 150-7 300-3.5
600-1.7      

 

Electrical Specifications 1

 

Output Ratings:

 

 

 

Output Voltage

 

0-600 V

 

Output Current

 

0-1.7 A

 

Output Power

 

1020 W

 

Output Ratings at the front panel binding posts:

 

 

 

Output Current

 

0-1.7 A

 

Output Power

 

1020 W

 

Line Regulation: 2

 

 

 

Voltage

 

20 mV

 

Current

 

0.5 mA

 

Load Regulation: 3

 

 

 

Voltage

 

20 mV

 

Current

 

2.5 mA

 

Meter Accuracy:

 

 

 

Voltage (0.5% of Vmax + 1 count)

 

7 V

 

Current (0.5% of Imax + 1 count)

 

0.03 A

 

Output Noise & Ripple:

 

 

 

Voltage rms

 

60 mV

 

Voltage (p-p) (0-20 MHz)

 

300 mV

 

Drift (8 hours): 4

 

 

 

Voltage (0.05% of Vmax)

 

300 mV

 

Current (0.1% of Imax)

 

1.7 mA

 

Temperature coefficient: 5

 

 

 

Voltage (0.02% of Vmax/° C)

 

120 mV

 

Current (0.03% of Imax/° C)

 

0.48 mA

 

Maximum Remote Sense:

 

 

 

Line Drop Compensation 6

 

5 V/line

 

OVP adjustment range: (5% to 110% of Vmax)

 

30-660 V

 

Efficiency: 7

 

85%

 

Interface Specifications 1,8

 

Program Resolution (16-bit):

 

 

 

Voltage

 

10.1 mV

 

Current

 

0.03 mA

 

OVP

 

10.1 mV

 

Program Accuracy:

 

 

 

Voltage (0.2% + 10 mV)

 

300 mV (+/- 0.35%)

 

Current (0.3% + 10 mA)

 

80 mA (+/- 0.1%)

 

OVP (0.5% + 100 mV)

 

6000 mV

 

Readback Resolution (16-bit):

 

 

 

Voltage

 

10.1 mV

 

Current

 

0.03 mA

 

Readback Accuracy:

 

 

 

Voltage (0.2% + 20 mV)

 

300 mV (+/- 0.35%)

 

Current (0.3% + 20 mA)

 

80 mA (+/- 0.1%)

 

 

 

 

 

1. Specifications indicate typical performance at 25 ° C +/- 5° C, nominal line input of 120 VAC.

 

2. For input voltage variation over the AC input voltage range, with constant rated load.

 

3. For 0-100% load variation, with constant nominal line voltage. Measured at the rear panel output connector unless stated otherwise.

 

4. Maximum drift over 8 hours with constant line, load and temperature, after 30 minute warm-up.

 

5. Change in output per ° C change in ambient temperature, with constant line and load.

 

6. Line drop is subtracted from total voltage available at supply output.

 


7. Typical efficiency at 115 VAC input and rated output power.

8. Apply accuracy specifications according to the following voltage program accuracy example:
    Set a model 20-130 power supply to 10 volts. The expected result will be within the range of 10 volts +/- 75 mV +/-
    0.12% of the set voltage of 10 volts.

 

 

 

General Specifications

 

Operational AC input voltage

 

85-250 VAC, 47-63 Hz; power factor corrected. Derate maximum output power for 900 W for AC input less than 95 V.

 

Maximum Input Current

 

13 A maximum at 100 VAC, 11 A mazimum at 120 VAC, 6 A maximum at 220 VAC

 

Power Factor

 

0.99 minimum for full load and 120 VAC input

 

Input Harmonic Distortion

 

Harmonics distortion complies with EN61000-3-2 limits

 

Switching Frequency

 

7.5 V to 300 V models: nominal 125 kHz (250 kHz output ripple); 600 V model: nominal 62.5 kHz (125 kHz output ripple)

 

Time Delay

 

4 s maximum from power on until output stable

 

Voltage Mode Transient Response Time

 

1 ms for output voltage to recover within 0.5 % of its previous level after a step change in load current of up to 50% of rated output

 

Maximum Voltage Differential

 

+/-600 VDC from output to safety ground

 

Remote On/Off and Interlock

 

2.5-15 V signal or TTL-compatible input, selectable logic

 

Remote Analog Programming

 

Voltage and current programming inputs (sources must be isolated): 0-5 k, 0-10 k resistances;0-5 V, 0-10 V (default) voltage sources

 

Remote Analog Monitoring

 

Voltage and current monitor outputs 0-5 V (default), 0-10 V ranges for 0-100% of output

 

Remote Programming and Monitoring Accuracy

 

1% zero to full scale output for the default range

 

Operating Temperature Range

 

32° F to 104 ° F (0° C to 40° C)

 

Storage Temperature Range

 

-40° F to 185° F (-40° C to 85° C)

 

Humidity Range

 

Up to 80% RH, non-condensing

 

Front Panel Voltage and Current Control

 

10-turn voltage and current potentiometers

 

Front Panel Voltage Control Resolution

 

0.02% of maximum voltage

 

AC Input Connector Type

 

IEC 320 connector

 

Main Output Connector

 

7.5 to 40 V models: nickel-plated copper bus bars; 60 V to 600 V models: 4-terminal wire clamp connector for DC output and local sense

 

Weight (one unit)

 

14 lb (6.4 kg) approx

 

Dimensions (H x W x D)

 

3.4 x 8.5 x 18.6” (86.4 x 216.0 x 472.2 mm)

 

Options

 

GPIB-XHR

 

GPIB Interface card (16-bit)

 

RS-232-XHR

 

RS-232 Interface card (16-bit)

 

ISOL-XHR

 

ISOL Interface card provides isolated analog control and readback

 

M13A

 

Locking knobs for front panel controls

 

M22a

 

No front binding posts

 

M61

 

Recessed front panel potentiometers

 

RM-XHR

 

19-inch rack mount kit for up to two XHR power supplies

 

Regulatory Approvals

 

CE-marked units meet: EN61010-1, EN61000-6-2 and EN61000-6-4; CSA C/US certified to UL61010-1B and CSA C22.2 No 1010.1; Meets USA EMC standard: FCC, part 15B, class A; Meets Canadian EMC standard: ICES-001, Class A.

 

Note: Specifications subject to change without notice.