General Specifications |
|
Operational AC Input Voltage |
|
|
|
170 V – 265 V, 45 to 66 Hz |
|
lin < 20 A nominal |
|
Nominal 120 V, Power output < 1 kW |
|
lin < 15 A nominal |
|
Power cord length |
|
2 m |
|
Power Factor Correction (PFC) |
|
Power factor correction to meet EN61000-3-2 Current Harmonics and EN61000-3-3 Voltage Fluctuations (IEC555) |
|
Inrush current |
|
Up to 100% of specified nominal current |
|
Input mains protection |
|
Circuit breaker switch on the front panel |
|
Environmental Conditions |
|
|
|
Storage temperature |
|
-20oC to 70oC |
|
Operating temperature |
|
0oC to 55oC (LCD to 50oC) |
|
Derate output current/power |
|
1% per oC from 30oC to 55oC |
|
Temperature Coefficient |
|
|
|
Voltage Programming |
|
0.01% per oC |
|
Current Programming |
|
0.02% per oC |
|
Voltage Readback |
|
0.01% per oC |
|
Current Readback |
|
0.02% per oC |
|
Long Term Drift |
|
Output change after 30 min. warm-up, over an interval of 8 hours under constant load, line and temperature conditions is 0.03%. |
|
Remote Sensing |
|
Up to 4 V can be dropped over the two load lines together (i.e. 1.5 V + 2.5 V). At 2.5 V a warning event will be generated, alerting over sense voltage drop condition, and at 4 V the module will be shut down. The load lines drop subtracts from the voltage available for the load. |
|
Output Programming Response |
|
Time rise and fall time with fall resistive load (10 to 90% and 90 to 10%) is 30-640 mSec. |
|
Current |
|
0.6% +/- 1 digit |
|
Isolation |
|
Output terminals can be floated up to +/- 240 VDC from chassis ground. |
|
Dimensions without feet
(H x W x D) |
|
5.25 x 19 x 22.5”/132.6 X 482.6 x 570.0 mm |
|
Weight |
|
|
|
XMP mainframe with controller |
|
26.2 lb (11.9 kg) |
|
1/8 width module |
|
3.9 lb (1.75 kg) |
|
2/8 width module |
|
5.5 lb (2.5 kg) |
|
3/8 width module |
|
7.5 lb (3.4 kg) |
|
Approvals |
|
CE-marked units meet: EN61010-1, EN61326, EN61000-3-2, and EN61000-3-3; UL Listed to UL61010-1; Meets USA EMC Standard FCC Part 15B Class A |
|
Note: Specifications subject to change without notice. |
|
|
 |
|

|
 |
 |