Xantrex Programmable Power
Programmable Power Products
Elgar, Sorensen and Xantrex Products
DC Products Bench Products AC Products Modular AC / DC Electronic Loads Custome Solutions
Overview Features Specifications Technical Diagrams Downloads Get a Quote  
XPD Series : Specifications
Specifications Available
7.5-67 18-30 33-16 60-9 120-4.5    

Electrical Specifications 1

 

Output Ratings:

 

 

 

Output Voltage 2

 

0-18 V

 

Output Current 3

 

0-30 A

 

Output Power

 

540 W

 

Line Regulation: 4

 

 

 

Voltage (0.01% of Vmax + 2 mV)

 

2 mV

 

Current (0.01% of Imax + 1 mA)

 

2 mA

 

Load Regulation: 5

 

 

 

Voltage (0.01% of Vmax + 2 mV)

 

4 mV

 

Current (0.01% of Imax + 5 mA)

 

4 mA

 

Meter Accuracy:

 

 

 

Voltage (1% of Vmax + 1 count)

 

0.3 V

 

Current (1% of Imax + 1 count)

 

0.4 A

 

Output Noise & Ripple:

 

 

 

Voltage (p-p) (0-20 MHz)

 

45 mV

 

Voltage rms

 

3 mV

 

Current rms 6

 

50 mA

 

Drift (60 minutes): 7

 

 

 

Voltage (0.15% of Vmax)

 

27 mV

 

Current (0.3% of Imax)

 

90 mA

 

Drift (8 hours): 8

 

 

 

Voltage (0.03% of Vmax)

 

5.4 mV

 

Current (0.05% of Imax)

 

15 mA

 

Temperature coefficient: 9

 

 

 

Voltage (0.015% of Vmax/° C)

 

2.7 mV

 

Current (0.02% of Imax/° C)

 

6 mA

 

OVP adjustment range: (5% to 110% of Vmax)

 

0.9-19.8 V

 

Efficiency: 10

 

83%

 

Interface Specifications 11

 

Program Resolution (16-bit):

 

 

 

Voltage

 

0.30 mV

 

Current

 

0.50 mA

 

OVP

 

0.30 mV

 

Program Accuracy:

 

 

 

Voltage (0.2% + 10 mV)

 

75 mV (+/- 0.12%)

 

Current (0.3% + 10 mA)

 

140 mA (+/- 0.1%)

 

OVP (0.5%) + 100 mV)

 

200 mV

 

Readback Resolution (16-bit):

 

 

 

Voltage

 

0.30 mV

 

Current

 

0.50 mA

 

Readback Accuracy:

 

 

 

Voltage (0.2% + 20 mV)

 

75 mV (+/- 0.12%)

 

Current (0.3% + 20 mA)

 

140 mA (+/- 0.1%)

 

 

 

 

 

1. All electrial specifications are represented at full operating temperature range for all models, unless otherwise stated.

 

2. Minimum output voltage is <0.15% of rated voltage at zero output setting.

 

3. Minimum output current is <0.2% of rated current at zero setting when measured with rated load resistance. Front output current limited to 30 A maximum.

 

4. For input voltage variation over the AC input voltage range, with constant rated load.

 

5. For 0-100% load variation, with constant nominal line voltage.

 

6. Current mode noise is measured from 10% to 100 % of rated output voltage, full current.

 

7. Maximum drift over 60 minutes with constant line, load and temperature, after power up.

 

8. Maximum drift over 8 hours with constant line, load and temperature, after 30 minutes warm-up.

 

9. Change in output per ° C change in ambient temperature, with constant line and load.

 

10. Typical efficiency at 120 V and full output power.

 


11. Interface specifications at 25° C +/- 5° C, nominal line input at 120 VAC.
      Apply accuracy specifications according to the following voltage program accuracy example:
      Set a model 18-30 power supply to 10 volts. The expected result will be within the range of 10 volts +/- 75 mV +/-
      0.12% of the set voltage of 10 volts.

 

 

 

General Specifications

 

Operational AC input voltage

 

84-264 VAC, 47-63 Hz; power factor corrected. Derate maximum output power to 450 W for AC input less that 95 V.

 

Maximum Input Current

 

7 A maximum at 100 VAC, 6 A maximum at 120 VAC, 3 A maximum at 220 VAC

 

Power Factor

 

0.98 minimum for full load at nominal voltage

 

Input Harmonic Distortion

 

Current harmonics meet IEC 1000-3-2

 

Switching Frequency

 

125 kHz (250kHz output ripple)

 

Time Delay

 

3 s maximum, from power on to output stable

 

Voltage Mode Transient Response Time

 

1 ms for output voltage to recover within o.5% of its previous level after a step change in load current of up to 50% of rated output

 

Maximum Voltage Differential

 

+/-300 VDC from output to safety ground

 

Remote On/Off and Interlock

 

5-15 V signal or TTL-compatible input, selectable logic. TTL input impedance: 2 k (in series with one diode drop)

 

Remote Analog Programming (Full Scale Input)

 

Voltage and current programming inputs (sources must be floating): 0-10 V (default) voltage sources. Input imedance (V and I): 20 k.

 

Remote Programming and Monitoring Accuracy

 

1% of full scale output for the default range

 

Operating Temperature Range

 

32° F to 122 ° F (0° C to 50° C)

 

Storage Temperature Range

 

-40° F to 185° F (-40° C to 85° C)

 

Humidity Range

 

Up to 95% RH, non-condensing

 

Front Panel Voltage and Current Control

 

10-turn voltage and current potentiometers

 

Front Panel Voltage Control Resolution

 

0.02% of maximum voltage

 

AC Input Connector Type

 

IEC 320 connector, appropriate power cord provided for destination country

 

Main Output Connector

 

Front panel: 5-way binding posts. Maximum current limit 30 A; Rear Panel: 7.5-18 V models: Bus bars; 33-120 V models: wire clamp connectors.

 

Weight (one unit)

 

9.0 lb (4.1 kg)

 

Dimensions (H x W x D)       

 

5.2 x 4.2 x 13” (134.7 x 109.2 x 330 mm)

 

Options

 

GPIB-XPD

 

GPIB Interface card (16-bit)

 

RS-232-XPD

 

RS-232 Interface card (16-bit)

 

RM-XHS

 

19-inch rack mount kit for up to four XPD, HPD or XT power supplies

 

Regulatory Approvals

 

CE-marked units meet: EN61010-1, EN61000-6-2 and EN61000-6-4; CSA C/US certified to UL3111-1 and CSA C22.2 No 1010.1; Meets USA EMC standard: FCC, part 15B, class A; Meets Canadian EMC standard: ICES-001, Class A.

 

Note: Specifications subject to change without notice.

To compare models, please download the XPD 500 W Data Sheet.


Investigate our discount web specials
  Product Configurator  
DC Electronic Loads
DC Modular Supply
Discontinued Products
Product Support
Contact Sales