Specifications Available
7.5-67 18-30 33-16 60-9 120-4.5    

Electrical Specifications 1

 

Output Ratings:

 

 

 

Output Voltage 2

 

0-33 V

 

Output Current 3

 

0-16 A

 

Output Power

 

528 W

 

Line Regulation: 4

 

 

 

Voltage (0.01% of Vmax + 2 mV)

 

3 mV

 

Current (0.01% of Imax + 1 mA)

 

2 mA

 

Load Regulation: 5

 

 

 

Voltage (0.01% of Vmax + 2 mV)

 

4 mV

 

Current (0.01% of Imax + 5 mA)

 

4 mA

 

Meter Accuracy:

 

 

 

Voltage (1% of Vmax + 1 count)

 

0.5 V

 

Current (1% of Imax + 1 count)

 

0.3 A

 

Output Noise & Ripple:

 

 

 

Voltage (p-p) (0-20 MHz)

 

45 mV

 

Voltage rms

 

3 mV

 

Current rms 6

 

30 mA

 

Drift (60 minutes): 7

 

 

 

Voltage (0.15% of Vmax)

 

49.5 mV

 

Current (0.3% of Imax)

 

48 mA

 

Drift (8 hours): 8

 

 

 

Voltage (0.03% of Vmax)

 

9.9 mV

 

Current (0.05% of Imax)

 

8 mA

 

Temperature coefficient: 9

 

 

 

Voltage (0.015% of Vmax/° C)

 

5 mV

 

Current (0.02% of Imax/° C)

 

3.2 mA

 

OVP adjustment range: (5% to 110% of Vmax)

 

1.7-36.3 V

 

Efficiency: 10

 

85%

 

Interface Specifications 11

 

Program Resolution (16-bit):

 

 

 

Voltage

 

0.55 mV

 

Current

 

0.27 mA

 

OVP

 

0.55 mV

 

Program Accuracy:

 

 

 

Voltage (0.2% + 10 mV)

 

75 mV (+/- 0.12%)

 

Current (0.3% + 10 mA)

 

115 mA (+/- 0.15%)

 

OVP (0.5%) + 100 mV)

 

330 mV

 

Readback Resolution (16-bit):

 

 

 

Voltage

 

0.55 mV

 

Current

 

0.27 mA

 

Readback Accuracy:

 

 

 

Voltage (0.2% + 20 mV)

 

75 mV (+/- 0.2%)

 

Current (0.3% + 20 mA)

 

115 mA (+/- 0.15%)

 

 

 

 

 

1. All electrial specifications are represented at full operating temperature range for all models, unless otherwise stated.

 

2. Minimum output voltage is <0.15% of rated voltage at zero output setting.

 

3. Minimum output current is <0.2% of rated current at zero setting when measured with rated load resistance. Front output current limited to 30 A maximum.

 

4. For input voltage variation over the AC input voltage range, with constant rated load.

 

5. For 0-100% load variation, with constant nominal line voltage.

 

6. Current mode noise is measured from 10% to 100 % of rated output voltage, full current.

 

7. Maximum drift over 60 minutes with constant line, load and temperature, after power up.

 

8. Maximum drift over 8 hours with constant line, load and temperature, after 30 minutes warm-up.

 

9. Change in output per ° C change in ambient temperature, with constant line and load.

 

10. Typical efficiency at 120 V and full output power.

 


11. Interface specifications at 25° C +/- 5° C, nominal line input at 120 VAC.
      Apply accuracy specifications according to the following voltage program accuracy example:
      Set a model 18-30 power supply to 10 volts. The expected result will be within the range of 10 volts +/- 75 mV +/-  
      0.12% of the set voltage of 10 volts.

 

 

 

General Specifications

 

Operational AC input voltage

 

84-264 VAC, 47-63 Hz; power factor corrected. Derate maximum output power to 450 W for AC input less that 95 V.

 

Maximum Input Current

 

7 A maximum at 100 VAC, 6 A maximum at 120 VAC, 3 A maximum at 220 VAC

 

Power Factor

 

0.98 minimum for full load at nominal voltage

 

Input Harmonic Distortion

 

Current harmonics meet IEC 1000-3-2

 

Switching Frequency

 

125 kHz (250kHz output ripple)

 

Time Delay

 

3 s maximum, from power on to output stable

 

Voltage Mode Transient Response Time

 

1 ms for output voltage to recover within o.5% of its previous level after a step change in load current of up to 50% of rated output

 

Maximum Voltage Differential

 

+/-300 VDC from output to safety ground

 

Remote On/Off and Interlock

 

5-15 V signal or TTL-compatible input, selectable logic. TTL input impedance: 2 k (in series with one diode drop)

 

Remote Analog Programming (Full Scale Input)

 

Voltage and current programming inputs (sources must be floating): 0-10 V (default) voltage sources. Input imedance (V and I): 20 k.

 

Remote Programming and Monitoring Accuracy

 

1% of full scale output for the default range

 

Operating Temperature Range

 

32° F to 122 ° F (0° C to 50° C)

 

Storage Temperature Range

 

-40° F to 185° F (-40° C to 85° C)

 

Humidity Range

 

Up to 95% RH, non-condensing

 

Front Panel Voltage and Current Control

 

10-turn voltage and current potentiometers

 

Front Panel Voltage Control Resolution

 

0.02% of maximum voltage

 

AC Input Connector Type

 

IEC 320 connector, appropriate power cord provided for destination country

 

Main Output Connector

 

Front panel: 5-way binding posts. Maximum current limit 30 A; Rear Panel: 7.5-18 V models: Bus bars; 33-120 V models: wire clamp connectors.

 

Weight (one unit)

 

9.0 lb (4.1 kg)

 

Dimensions (H x W x D)       

 

5.2 x 4.2 x 13” (134.7 x 109.2 x 330 mm)

 

Options

 

MGA, MGP

 

GPIB Interface card, IEEE488.1
GPIB Interface card (16-bit), IEEE488.2 Multi Channel Master

 

MRA

 

RS-232 Interface card (16-bit)

 

RM-XPDG-2

 

19-inch rack mount kit for up to four XPD, HPD or XT power supplies

  M1   Delete front knobs and outputs
  M13A   Locking knobs
  MCA   Multi channel slave (for use with MGP)

 

Regulatory Approvals

 

CE-marked units meet: EN61010-1, EN61000-6-2 and EN61000-6-4; CSA C/US certified to UL3111-1 and CSA C22.2 No 1010.1; Meets USA EMC standard: FCC, part 15B, class A; Meets Canadian EMC standard: ICES-001, Class A.

 