Electrical Specifications 1 |
|
Output Ratings: |
|
|
|
Output Voltage 2 |
|
0-7.5 V |
|
Output Current 3 |
|
0-67 A |
|
Output Power |
|
502.5 W |
|
Line Regulation: 4 |
|
|
|
Voltage (0.01% of Vmax + 2 mV) |
|
2 mV |
|
Current (0.01% of Imax + 1 mA) |
|
2 mA |
|
Load Regulation: 5 |
|
|
|
Voltage (0.01% of Vmax + 2 mV) |
|
2 mV |
|
Current (0.01% of Imax + 5 mA) |
|
4 mA |
|
Meter Accuracy: |
|
|
|
Voltage (1% of Vmax + 1 count) |
|
0.2 V |
|
Current (1% of Imax + 1 count) |
|
0.8 A |
|
Output Noise & Ripple: |
|
|
|
Voltage (p-p) (0-20 MHz) |
|
45 mV |
|
Voltage rms |
|
3 mV |
|
Current rms 6 |
|
150 mA |
|
Drift (60 minutes): 7 |
|
|
|
Voltage (0.15% of Vmax) |
|
11.3 mV |
|
Current (0.3% of Imax) |
|
201 mA |
|
Drift (8 hours): 8 |
|
|
|
Voltage (0.03% of Vmax) |
|
2.3 mV |
|
Current (0.05% of Imax) |
|
34 mA |
|
Temperature coefficient: 9 |
|
|
|
Voltage (0.015% of Vmax/° C) |
|
1.2 mV |
|
Current (0.02% of Imax/° C) |
|
13.4 mA |
|
OVP adjustment range: (5% to 110% of Vmax) |
|
0.4-8.3 V |
|
Efficiency: 10 |
|
81% |
|
Interface Specifications 11 |
|
Program Resolution (16-bit): |
|
|
|
Voltage |
|
0.13 mV |
|
Current |
|
1.12 mA |
|
OVP |
|
0.13 mV |
|
Program Accuracy: |
|
|
|
Voltage (0.2% + 10 mV) |
|
10 mV (+/- 0.12%) |
|
Current (0.3% + 10 mA) |
|
250 mA (+/- 0.1%) |
|
OVP (0.5%) + 100 mV) |
|
80 mV |
|
Readback Resolution (16-bit): |
|
|
|
Voltage |
|
0.13 mV |
|
Current |
|
1.12 mA |
|
Readback Accuracy: |
|
|
|
Voltage (0.2% + 20 mV) |
|
30 mV (+/- 0.12%) |
|
Current (0.3% + 20 mA) |
|
250 mA (+/- 0.1%) |
|
|
|
|
|
1. All electrial specifications are represented at full operating temperature range for all models, unless otherwise stated. |
|
2. Minimum output voltage is <0.15% of rated voltage at zero output setting. |
|
3. Minimum output current is <0.2% of rated current at zero setting when measured with rated load resistance. Front output current limited to 30 A maximum. |
|
4. For input voltage variation over the AC input voltage range, with constant rated load. |
|
5. For 0-100% load variation, with constant nominal line voltage. |
|
6. Current mode noise is measured from 10% to 100 % of rated output voltage, full current. |
|
7. Maximum drift over 60 minutes with constant line, load and temperature, after power up. |
|
8. Maximum drift over 8 hours with constant line, load and temperature, after 30 minutes warm-up. |
|
9. Change in output per ° C change in ambient temperature, with constant line and load. |
|
10. Typical efficiency at 120 V and full output power. |
|
11. Interface specifications at 25° C +/- 5° C, nominal line input at 120 VAC.
Apply accuracy specifications according to the following voltage program accuracy example:
Set a model 18-30 power supply to 10 volts. The expected result will be within the range of 10 volts +/- 75 mV +/-
0.12% of the set voltage of 10 volts.
|
|
|
|
General Specifications |
|
Operational AC input voltage |
|
84-264 VAC, 47-63 Hz; power factor corrected. Derate maximum output power to 450 W for AC input less that 95 V. |
|
Maximum Input Current |
|
7 A maximum at 100 VAC, 6 A maximum at 120 VAC, 3 A maximum at 220 VAC |
|
Power Factor |
|
0.98 minimum for full load at nominal voltage |
|
Input Harmonic Distortion |
|
Current harmonics meet IEC 1000-3-2 |
|
Switching Frequency |
|
125 kHz (250kHz output ripple) |
|
Time Delay |
|
3 s maximum, from power on to output stable |
|
Voltage Mode Transient Response Time |
|
1 ms for output voltage to recover within 0.5% of its previous level after a step change in load current of up to 50% of rated output |
|
Maximum Voltage Differential |
|
+/-300 VDC from output to safety ground |
|
Remote On/Off and Interlock |
|
5-15 V signal or TTL-compatible input, selectable logic. TTL input impedance: 2 k (in series with one diode drop) |
|
Remote Analog Programming (Full Scale Input) |
|
Voltage and current programming inputs (sources must be floating): 0-10 V (default) voltage sources. Input imedance (V and I): 20 k. |
|
Remote Programming and Monitoring Accuracy |
|
1% of full scale output for the default range |
|
Operating Temperature Range |
|
32° F to 122 ° F (0° C to 50° C) |
|
Storage Temperature Range |
|
-40° F to 185° F (-40° C to 85° C) |
|
Humidity Range |
|
Up to 95% RH, non-condensing |
|
Front Panel Voltage and Current Control |
|
10-turn voltage and current potentiometers |
|
Front Panel Voltage Control Resolution |
|
0.02% of maximum voltage |
|
AC Input Connector Type |
|
IEC 320 connector, appropriate power cord provided for destination country |
|
Main Output Connector |
|
Front panel: 5-way binding posts. Maximum current limit 30 A; Rear Panel: 7.5-18 V models: Bus bars; 33-120 V models: wire clamp connectors. |
|
Weight (one unit) |
|
9.0 lb (4.1 kg) |
|
Dimensions (H x W x D) |
|
5.2 x 4.2 x 13” (134.7 x 109.2 x 330 mm) |
|
Options |
|
GPIB-XPD |
|
GPIB Interface card (16-bit) |
|
RS-232-XPD |
|
RS-232 Interface card (16-bit) |
|
RM-XHS |
|
19-inch rack mount kit for up to four XPD, HPD or XT power supplies |
|
Regulatory Approvals |
|
CE-marked units meet: EN61010-1, EN61000-6-2 and EN61000-6-4; CSA C/US certified to UL3111-1 and CSA C22.2 No 1010.1; Meets USA EMC standard: FCC, part 15B, class A; Meets Canadian EMC standard: ICES-001, Class A. |
|
Note: Specifications subject to change without notice. |
To compare models, please download the XPD 500 W Data Sheet. |