Xantrex Programmable Power
Programmable Power Products
Elgar, Sorensen and Xantrex Products
DC Products Bench Products AC Products Modular AC / DC Electronic Loads Custome Solutions
Overview Features Specifications Technical Diagrams Downloads Get a Quote  
XPH Series : Specifications
Specifications Available
18-10 35-5 35-4D 35-4T 42-10 75-2D  

Electrical Specifications

 

Output Ratings:

 

 

 

Output voltage

 

0 - 42 V

 

Output current

 

0 - 10 A

 

Outputs

 

1

 

Output power

 

420 W

 

Operating mode

 

Constant voltage or constant current with automatic cross-over and indication

 

Voltage setting

 

By coarse and fine controls

 

Current setting

 

By single logarithmic control

 

Output impedance

 

Typically <5mW in constant voltage mode. Typically >20kW in constant current mode.

 

Line regulation

 

<0.01% of max. output for a 10% line voltage change

 

Load regulation

 

<0.01% of max. output for a 90% load change

 

Ripple and noise (20 MHz bandwidth)

 

Typically <2 mV rms, <10 mV pk-pk

 

Transient response

 

<200ms to within 50 mV of set level for 90% load change

 

Temperature coefficient

 

Typically <100ppm/oC

 

Output protection

 

Outputs will withstand forward voltages up to 40 V

 

Status indication

 

Output ON lamps. Constant current mode lamps.

 

Output switch

 

Electronic. Preset voltage/current displayed with output off.

 

Output terminals

 

4mm terminals on 19mm (0.75") pitch. Special safety terminals on XPH 75-2.

 

Meters (main outputs):

 

 

 

Meter types

 

Separate 3 digit meters for voltage and current with 14mm (0.56") LED displays. Reading rate 4/sec (4 digit voltmeter on XPH 75-2)

 

Meter resolution

 

100 mV, 10 mA

 

Meter accuracy:

 

 

 

Voltage

 

0.3% +/- 1 digit

 

Current

 

0.6% +/- 1 digit

 

XPH 42-10 Model

 

Output protection

 

As XPH series but with limits of 48 V. Over-temperature trip on XPH 42-10.

 

Remote selection

 

Switch selectable as Local or Remote

 

Connection

 

Remote sense connections via spring loaded connectors

 

Meter types

 

Separate 4 digit meters for voltage and current with 14mm (0.56") LED displays. Reading rate 4/sec.

 

Meter resolutions

 

10 mV, 10 mA

 

Meter accuracies

 

voltage 0.3% +/- 2 digit. Current 0.6% +/- 2 digit

 

General Specifications

 

Cooling

 

Convection (Fan assisted for XPH 42-10)

 

Output terminals:

 

 

 

Standard type

 

4mm "binding post" terminals suitable for plugs or wires

 

Optional (all models)

 

4mm safety sockets, suitable for shrouded plugs

 

AC input

 

Factory set: 110 to 120 VAC +/- 10% or 220 - 240 VAC +/- 10%, 50/60 Hz Installation Category ll

 

Consumption

 

800 VA

 

Operating range

 

5oC to 40oC, 20% to 80% RH

 

Storage range

 

-40oC to 70oC

 

Environmental

 

Indoor use at altitudes to 2000m, Pollution Degree 2

 

Safety

 

Complies with EN61010-1

 

EMC

 

Complies with EN61326

 

Dimensions (HxWxD)

 

160 x 140 x 320mm

 

Unit weight

 

7.9 lbs/3.6 kg

 

Warranty

 

3 years

 

Regulatory Approvals

 

CE-marked units meet: EN61010-1 and EN 61326

 

Note: Specifications subject to change without notice.


Investigate our discount web specials