Electrical Specifications |
| |
Output voltage |
|
0-30 V |
| |
Output current |
|
0-2 A |
| |
Outputs |
|
3 |
| |
Output power |
|
125 W |
| |
Operating mode |
|
Constant voltage or constant current with automatic cross-over and indication |
| |
Voltage setting |
|
By coarse and fine controls |
| |
Current setting |
|
By single logarithmic control |
| |
Line regulation |
|
<0.01% of max. output for a 10% line voltage change |
| |
Load regulation |
|
<0.01% of max. output for a 90% load change |
| |
Output impedance |
|
Typically <5mW in constant voltage mode.
Typically >50kW in constant current mode. |
| |
Ripple and noise (200MHz) |
|
Typically <1mV rms (CV mode) |
| |
Transient response |
|
<20ms to within 50mV of set level for 90% load change |
| |
Temperature coefficient |
|
Typically <100ppm/oC |
| |
Output protection |
|
Outputs will withstand forward voltages of up to 20 V above the rated output voltage. Reverse protection by diode clamp for current up to 3 A |
| |
Status indication |
|
Output ON lamps. Constant current mode lamps |
| |
Output switch |
|
Electronic. Preset voltage and current displayed when output is off |
| |
Output terminals |
|
4mm terminals on 19mm (0.75") pitch |
| |
Meter resolutions |
|
100 mV, 10 mA |
| |
Meter accuracy: |
|
|
| |
Voltage |
|
0.3% +/- 1 digit |
| |
Current |
|
0.6% +/- 1 digit |
| |
Logic Output |
| |
Voltage |
|
1.5 V - 5 V, variable setting |
| |
Voltage accuracy |
|
+/- 3% |
| |
Current limit |
|
1 A minimum |
| |
Load regulation |
|
<0.5% for a 90% load change |
| |
Line regulation |
|
<0.1% for a 10% line voltage change |
| |
Ripple and noise (20MHz bandwidth) |
|
Typically <1mV rms (CV mode) |
| |
Output Protection |
|
Output will withstand up to 16V forward voltage. Diode lamp reverse protection for currents to 3A. |
| |
Output terminals |
|
4mm terminals on 19mm (0.75") pitch |
| |
Status indication |
|
Current limit lamp |
| |
General Specifications |
| |
AC input |
|
115 V or 230 VAC +/- 10% (adjustable internally, option HV for factory set 230 VAC input) Installation Category ll |
| |
Power consumption |
|
320 VA |
| |
Operating range |
|
5oC to 40oC, 20% to 80% RH |
| |
Storage range |
|
-40oC to + 70oC |
| |
Environmental |
|
Indoor use at altitudes to 2000m, Pollution Degree 2 |
| |
Cooling |
|
Silent fan-less convection cooling |
| |
Safety |
|
Complies with EN61010-1 |
| |
EMC |
|
Complies with EN61326 |
| |
Dimensions (HxWxD) |
|
6.3 x 10.2 x 11.6"/160 X 260 x 295mm |
| |
Weight |
|
16.5 lb/7.5 kg |
| |
Warranty |
|
3 years |
| |
Regulatory Approvals |
| |
CE-marked units meet: EN61010-1 and EN61326 |
| |
| Note: Specifications subject to change without notice. |