Electrical Specifications 1

 

Output Ratings:

 

 

 

Output Voltage

 

0-15 V

 

Output Current

 

0-4 A

 

Output Power

 

60 W

 

Line Regulation: 2

 

 

 

Voltage (0.01% of Vmax + 2 mV)

 

2 mV

 

Current (0.01% of Imax + 250 µA )

 

0.4 mA

 

Load Regulation: 3

 

 

 

Voltage (0.01% of Vmax + 2 mV)

 

2 mV

 

Current (0.01% of Imax + 250 µA)

 

0.4 mA

 

Output Noise & Ripple:

 

 

 

Voltage rms

 

<1 mV

 

Current rms

 

<1 mA

 

Meter Accuracy:

 

 

 

Voltage (1% of Vmax + 1 count)

 

0.25 V

 

Current (1% of Imax + 1 count)

 

0.05 A

 

Drift (8 hours): 4

 

 

 

Voltage (0.02% of Vmax)

 

3 mV

 

Current (0.03% of Imax)

 

1.2 mA

 

Temperature coefficient: 5

 

 

 

Voltage (0.015% of Vmax/° C)

 

2.25 mV

 

Current (0.02% of Imax/° C)

 

0.8 mA

 

Interface Specifications 1,6

 

Program Resolution (16-bit):

 

 

 

Voltage

 

0.25 mV

 

Current

 

0.07 mA

 

OVP

 

0.25 mV

 

Program Accuracy:

 

 

 

Voltage (0.2% + 10 mV)

 

20 mV (+/- 0.1%)

 

Current (0.3% + 10 mA)

 

70 mA (+/- 0.15%)

 

OVP (0.5%) + 100 mV)

 

150 mV

 

Readback Resolution (16-bit):

 

 

 

Voltage

 

0.25 mV

 

Current

 

0.07 mA

 

Readback Accuracy:

 

 

 

Voltage (0.2% + 20 mV)

 

10 mV (+/- 0.1%)

 

Current (0.3% + 20 mA)

 

70 mA (+/- 0.15%)

 

 

 

 

 

1. Specifications indicate typical performance at 25° C +/- 5° C, nominal line input of 115 VAC.

 

2. For input voltage variation over the AC input voltage range, with constant rated load.

 

3. For 0-100% load variation, with constant nominal line voltage.

 

4. Maximum drift over 8 hours with constant line, load and temperature, after 30 minutes warm-up.

 

5. Change in output per ° C change in ambient temperature, with constant line and load.

6. Apply accuracy specifications according to the following voltage program accuracy example:
    Set a model 15-4 power supply to 10 volts.
    The expected result will be within the range of 10 volts +/- 20 mV +/- 0.1% of the set voltage of 10 volts.

 

 

 

General Specifications

 

Operational AC input voltage

 

Standard: 115 VAC +/- 10%. 57-63 Hz; Optional: 110/220/230/240 VAC +/-10%, 47-63 Hz

 

AC Input Current

 

Single Unit: 1.2 A, Dual Unit: 2.4 A, Triple Unit: 3.6 A, Quad Unit: 4.8 A, at 115 VAC

 

Voltage Mode Transient Response Time

 

<100 µs recovery to 0.05% band, +/-50% load change in the range of 25% to 100% of the rated load

 

Operating Ambient Temperature

 

0° C to 30° C for full rated output. Above 30° C, derate output linearly to zero at 70° C

 

Storage Temperature Range

 

-55° C to 85° C

 

Humidity Range

 

0 to 80% HR, non-condensing

 

Front Panel Voltage and Current Control

 

10-turn voltage and 1-turn current potentiometers (10-turn current optional)

 

Front Panel Voltage Control Resolution

 

0.02% of maximum voltage

 

AC Input Connector Type

 

IEC 320 connector

 

Weight (one unit)

 

Approximately 7.7 lb (3.5 kg)

 

Dimensions (H x W x D)

 

5.2 x 4.2 x 11.7” (132 x 109.2 x 297 mm)

 

Options

 

MGA

 

GPIB Interface card (16-bit)

 

MRA

 

RS-232 Interface card (16-bit)

 

MAA

 

Analog programming interface card

 

M1

 

110 VAC Input (50/60 Hz)

 

M2

 

220 VAC Input (50/60 Hz)

 

M3

 

230 VAC Input (50/60 Hz)

 

M4

 

240 VAC Input (50/60 Hz)

 

M11

 

10-turn current potentiometer

 

M13A

 

Locking knobs for front panel controls

 

M43

 

Switching selectable Input 110 VAC or 220 VAC

 

RM-XPDG-2

 

19-inch rack mount kit for up to four XT, XPD or HPD power supplies

 

Analog Programming

 

Remote On/Off and Interlock

 

2-25 VDC high. <0.8 VDC low. User-selectable. 

 

Remote analog Programming Option

 

0-10 VDC for 0-100% of rated voltage or current ±0.1%, 0-10 kΩ for 0-100% of rated voltage or current ±0.1%

 

Remote Monitoring

 

0-10 VDC for 0-100% or rated voltage or current ±0.1%

 

Over Voltage Protection Trip Range

 

3 V to full output +10%

 

Tracking Accuracy

 

+/- 1% for series operation

 

Regulatory Approvals

 

CSA certified to CSA C22.2 No 107.1; Meets USA EMC standard: FCC, part 15B, class A; Meets Canadian EMC standard: ICES-001, Class A (Models up to and including 120V).

 